HVAC Replacement Cost Calculator (2026)

Enter what you have, what you want, capacity, efficiency and your state. You get an installed-cost estimate with every line listed, energy cost at your state’s EIA prices, all four system options compared over 10 years, and a check on any HVAC quote.

HVAC Replacement Cost Calculator

Price a central AC, gas furnace, ducted heat pump, or matched AC + furnace change-out. Capacity prices equipment; a shared delivered heat load drives heating energy. Labor follows May 2025 BLS wages by trade.

One ton equals 12,000 Btu/h of cooling. Heat-pump tons are cooling capacity, not furnace heating output.
Prices the furnace only. Published bands do not say input versus delivered output, so they are not used as the heating load.
Planning hint only (about 500 to 600 sq ft per ton). Not a Manual J load calculation.
Shared useful heat for every heating option. Furnace fuel = this ÷ AFUE. Heat-pump heating uses the same delivered load with HSPF2. Default 60 MMBtu is our planning assumption.
Affects cooling operating cost only. Enter the installed model’s certified SEER2.
Applied once to the delivered heat load. Federal non-weatherized gas furnace minimum is 80% AFUE as of 2026.
Federal national split heat-pump minimum is 7.5 HSPF2 / 14.3 SEER2. ENERGY STAR ducted voluntary criteria are higher (7.8 / 15.2).
Defaults off for heat pumps: Angi by-ton pages do not prove haul-away is included or excluded; we treat disposal as a site-quote item and do not auto-charge it. Turn on only if your written quote bills haul-away separately. Optional add-on. Angi Insider HVAC permit $250-$400 (Oct 30 2026) when checked. Prices gas piping only. Combustion venting, chimney or flue work stays a quote exclusion unless the contractor itemizes it. Complete duct labor uses sheet metal workers (47-2211). Full new-duct HVAC jobs are a different published project band and are not stacked on this line.
Estimated installed cost
$7,410
Planning range: $6,810 to $8,010
Full range: $6,200 to $8,600. Ranges apply to the total, not to each line.

Equipment, labor and the extras listed below. State and metro figures below are total installed costs with labor scaled by local wages—not labor-only totals. Equipment and permit fees stay national.

$460energy per year at your state’s average price
$12,01010 years: installed cost plus energy
40%of the installed cost is labor
Like-for-like Central air conditioner replacement. Energy shown is cooling-only for the selected tonnage and SEER2.
Capacity check: 3 tons sits near the 500-600 sq ft/ton planning hint for 1800 sq ft. Still confirm with Manual J and Manual S.
National planning check for an ordinary residential central split-system cooling-only air conditioner under 10 CFR 430.32(c): SEER2 floor 13.4 (10 CFR 430.32(c)(5)). Confirm the certified rating on the installed model.
Wage area: US average (national selection). Active trades for this estimate: – HVAC mechanics (49-9021): origin U (US national mean (national selection)). BLS OEWS May 2025 payroll employees only; excludes self-employed and benefits. Wage proxy, not a contractor price index. EIA electricity: 18.19 cents/kWh (US average); gas: $15.34/Mcf for year 2025. Local wage factors: US average (1.000) for all trades. Applicable trades on this estimate: HVAC mechanics (49-9021).

Cost breakdown

ItemLowTypicalHigh
Central air conditioner, 3 tons, installed$5,800$6,800$7,800
Remove and dispose of the old equipment$150$280$400
HVAC permit and inspection$250$330$400
Total$6,200$7,410$8,600

All four options (shared loads)

Heating options use the same delivered heat load. Cooling options use the same tonnage × hours cooling load. A gas furnace row is heating-only. Matched AC + furnace is one combined change-out, not AC plus furnace stacked. Rows are not interchangeable certified installed jobs—read each scope note (heat-pump Angi by-ton base leaves air-handler and haul-away ambiguous). Energy / yr rounds heating and cooling shares to the nearest $10, then sums those shares. 10-year cost is typical installed plus 10 × that energy total. $/yr of life is typical installed ÷ planning life years (illustrative midpoints: 18 years for AC, heat pump and matched package; 20 years for gas furnace).

SystemInstalledEnergy / yr10-year$/yr of lifeScope
Central air conditioner, 3 ton (cool only)$7,410$460$12,010$410HomeGuide AC by-ton installed base (ductwork changes excluded); removal/permit as toggled
Gas furnace, 60-70 kBTU (heat only)$6,960$960$16,560$350HomeGuide furnace by labeled kBTU; heating-only energy
Air-source heat pump (ducted), 3 ton$5,050$1,920$24,250 (incomplete HP base)$280Incomplete Angi by-ton base (www.angi.com): handler/haul-away not demonstrated; removal off; permit off (optional add-on); not HomeGuide $10k-$25k+ with-handler scope
Matched central AC + gas furnace, 3 ton class$8,610$1,420$22,810$480Matched combined change-out band (our per-ton interpolation); not the same certified installed job as the heat-pump row

Is your HVAC quote fair?

Verdict updates as you edit this field. Blank clears it.

This is a planning estimate, not a quote. Get at least two written quotes for the same capacity, efficiency and scope. How we calculate.

Prices checked November 25, 2026. Sources: HomeGuide, Angi, This Old House, ENERGY STAR, 10 CFR 430.32, EIA, BLS OEWS May 2025.

How much does HVAC replacement cost in 2026?

A like-for-like replacement of a 3-ton central air conditioner with existing ducts, removal of the old equipment and an HVAC permit comes to about $7,410 at US average labor rates in our model. The planning range is $6,810 to $8,010 and the full range $6,200 to $8,600.

HomeGuide prices a 3-ton central AC installed at $5,800 to $7,800 for a basic installation without ductwork (July 25, 2025). This Old House puts standalone AC at $4,000 to $8,000 and AC plus furnace with simple ducts at $5,000 to $12,500 (June 12, 2026). HomeGuide’s HVAC guide prices a combined change-out with existing ducts at $5,000 to $11,000 (August 27, 2025). Those are separate scopes: this calculator never adds a standalone AC installed total to a standalone furnace installed total to invent a package price.

Cost by system type

The rows below share a delivered annual heat load of 60 MMBtu (our planning default) and the same 3-ton cooling class where the system cools. Heat-pump removal and permit default off because Angi by-ton pages do not prove haul-away is included or excluded, and Angi DIY vs Pro says labor usually covers local permits (Cost Factors lists permits $50-$300 separately — not auto-added). These rows are not interchangeable certified installed jobs—read the scope column. Capacity follows each type’s published table (matched package uses our interpolation). Efficiency changes operating cost only.

SystemCapacity usedScope (not interchangeable)Typical installedEnergy per yearHeating share10-year cost
Central air conditioner3 tons coolingcooling only; HomeGuide AC by-ton base (ductwork excluded)$7,410$460$0$12,010
Gas furnace60-70 kBTU/h labeledheating only; HomeGuide furnace by labeled kBTU$6,960$960$960$16,560
Air-source heat pump (ducted)3 tons cooling classincomplete Angi by-ton base (handler/haul-away not demonstrated); removal off; permit off; 10-year uses this incomplete installed base — not HomeGuide with-handler $10k-$25k+$5,050$1,920$1,460$24,250
Matched central AC + gas furnace3 tons cooling classmatched combined change-out (our per-ton interpolation); not the same job as the heat-pump row$8,610$1,420$960$22,810
Shared delivered heat = 60 MMBtu. Furnace fuel = delivered ÷ AFUE. Heat-pump heating uses the same delivered load with HSPF2. Cooling uses tons × 12,000 × 1,000 hours ÷ SEER2. Energy shares round to the nearest $10; Energy per year is the sum of those rounded heating and cooling shares. A furnace row is not a whole-home HVAC operating cost. Heat-pump 10-year cost sits on an incomplete installed base. Modeled estimates, not quotes.

A 2-ton central AC like-for-like job is about $6,510 typical in our model; a 5-ton job is about $8,860 typical. HomeGuide’s published 5-ton basic installed band is $7,000-$9,500+ (open-ended upper; ductwork changes excluded); our model stores $9,500 as an illustrative numeric cutoff, so a 5-ton row with removal and permit can show a model upper near $10,300—that upper is not a closed published HomeGuide ceiling. A 40-50 kBTU labeled gas furnace is about $5,860; a 90-120 kBTU labeled furnace is about $9,510. A 3-ton ducted heat pump (removal off, permit off; incomplete Angi by-ton base) is about $5,050. A matched 3-ton-class AC + furnace change-out is about $8,610, which is not equal to adding the AC-only and furnace-only rows ($7,410 + $6,960) and is not the same certified installed job as the heat-pump figure.

What changes the price

Capacity, not square footage as certainty

HomeGuide states that one ton cools approximately 500 to 600 square feet, then lists layout, ceiling height, insulation, climate and sun as other factors. The DOE Building America fact sheet directs a Manual J load calculation, then Manual S equipment selection. This tool treats square footage as a planning hint only.

Efficiency tables are not adders

HomeGuide publishes separate installed tables by SEER for AC and by AFUE for furnaces. Those bands overlap the capacity tables. Our model prices capacity for the installed total and uses SEER2, AFUE and HSPF2 only for operating cost. There is no universal per-SEER multiplier on top of tonnage prices.

Heat-pump scope

Angi (canonical www.angi.com; October 28, 2026) lists ducted heat-pump installed prices by ton (for example 3 tons $3,900 to $6,200). That page does not unambiguously state whether an air handler or haul-away is included—those are site-quote items / our modeling assumptions. DIY vs Pro says labor usually covers local permits; Cost Factors separately lists permits $50 to $300. HomeGuide (October 30, 2025) lists air-source installed at $10,000 to $25,000+ explicitly with a handler in the footnote—a different disclosed scope, not a same-area/size certified equivalent of the Angi entry band; its other-additions disposal is $200 to $500. We use the Angi capacity rows for the heat-pump base, never auto-add a handler, never claim the Angi-to-HomeGuide gap is entirely the handler, default removal off, and default permit off so a separately assumed permit fee is not auto-charged (optional checkbox adds Angi Insider HVAC permit $250-$400 only when opted in). This Old House and Angi’s HVAC price guide also publish $4,500 to $8,000 ducted heat-pump bands used as cross-checks.

Ducts, permits and disposal

HomeGuide’s AC page and the gas furnace page put minor duct work at $300 to $1,500 and replacement ducts at $1,400 to $5,600+ (AC basic by-ton bands exclude ductwork changes). Complete duct labor uses sheet metal workers (47-2211). Angi Insider price guide, exact row HVAC permit $250-$400 (October 30, 2026) — optional; off by default on heat pumps. HomeGuide gas furnace page, exact row disposal if excluded $150-$400 (December 31, 2025). Heat-pump estimates default removal and permit off. Turning on full duct replacement on a 3-ton AC job raises the typical total from $7,410 to $10,910 in our model. A bare equipment-plus-install estimate with removal and permit off is about $6,800.

Location

Labor in each line is scaled with May 2025 Bureau of Labor Statistics wages by trade: HVAC mechanics (49-9021), sheet metal workers (47-2211), electricians (47-2111) and plumbers (47-2152). Equipment and permit fees stay at national averages. For the default 3-ton AC swap, the total installed estimate (not a labor-only figure) is lowest in Alabama and Arkansas (tied at about $6,790) and highest in District of Columbia (about $8,330). The official pack offers 385 metros that have at least one direct core observation for 49-9021 (example: Abilene, TX CBSA 10180 factors HVAC 0.842, electrical 0.746). Each active trade shows provenance L, S or U with the full CBSA name; S falls back to the metro’s first-listed primary state, not a different selector state. BLS OEWS covers payroll employees only and excludes self-employed workers and benefits; it is a wage proxy, not a contractor price index.

Running cost and efficiency

Heating alternatives share one user-supplied delivered annual heat load (default 60 MMBtu, our assumption). Furnace fuel MMBtu = delivered ÷ AFUE (AFUE applied once). A labeled 60-70 kBTU furnace band is not treated as useful load: published capacity bands do not identify input versus output. Cooling delivered Btu = tons × 12,000 × 1,000 cool hours for systems that cool. Heat-pump heating kWh = delivered MMBtu × 1,000,000 ÷ HSPF2 ÷ 1,000. Gas is priced with EIA residential $/Mcf and 1.037 MMBtu per Mcf.

With the shared 60 MMBtu delivered heat load at US average EIA prices, furnace heating energy is about $960 per year at 92% AFUE, while the heat-pump heating share alone is about $1,460 (HSPF2 7.5) and its cooling share about $460; those rounded shares sum to $1,920 combined heat-plus-cool. The AC-only cooling energy is about $460. Energy figures round each share to the nearest $10; when both shares appear, the yearly total is their sum. Compare heating shares to heating shares, or whole-home rows to whole-home rows.

Electricity uses EIA Table 5.6.B (US average 18.19 cents per kWh, year to date through September 2026). Gas uses EIA residential gas prices (US average $15.34 per thousand cubic feet for 2025, with labeled 2024 fallback where needed). Federal warnings follow 10 CFR 430.32 for ordinary residential central split-system cooling-only AC and air-source heat pumps. Split heat pumps use the national floors SEER2 14.3 / HSPF2 7.5. Cooling-only split AC uses the national SEER2 13.4 floor in the North (states outside the Southeast and Southwest lists); in the Southeast and Southwest, SEER2 floors depend on AHRI-certified cooling capacity at 45,000 Btu/h (14.3 below; 13.8 at or above). Southwest states also have EER2 floors that depend on SEER2 and that same certified capacity (11.7 / 11.2 when SEER2 is below 15.2; 9.8 when SEER2 is 15.2 or higher). Those regional AC tables do not apply to heat pumps. Nominal tons cannot establish legal class. ENERGY STAR voluntary ducted criteria remain higher (HSPF2 7.8 / SEER2 15.2 / EER2 11.0; checked November 25, 2026).

Tax credit timing (section 25C)

IRS Instructions for Form 5695 (2025) What’s New: you cannot claim energy efficient home improvement credits for property placed in service after December 31, 2025. A system placed in service in 2026 does not qualify for the federal Section 25C credit. The estimate assumes no federal credit.

How to check an HVAC quote

Run the total through the quote checker, then confirm the written scope covers:

  • Brand, model, capacity (tons or labeled kBTU) and efficiency (SEER2, AFUE or HSPF2)
  • Whether the job is AC-only, furnace-only, heat pump, or a matched AC + furnace change-out
  • Removal and disposal of the old equipment
  • The permit where your city requires one
  • Duct, refrigerant, thermostat and electrical work, itemized
  • For matched systems, indoor and outdoor units listed as a rated match
  • A licensed, insured installer and a written labor warranty

How this calculator works

  1. Base installed price. Capacity tables from HomeGuide (AC July 25 2025; gas furnace December 31 2025), Angi heat pump by ton (October 28 2026), and combined change-out bands from HomeGuide HVAC (August 27 2025) plus This Old House (June 12 2026). Typical is the midpoint of each published low/high row. Labor share 40% is our assumption.
  2. No stacked scopes. Matched AC + furnace uses one combined band with our per-ton interpolation (formula and rendered capacity table disclosed below). Efficiency installed tables are disclosed but not added to capacity prices. Heat-pump handler is not auto-added on top of Angi capacity rows; haul-away and a separately assumed permit fee are not auto-charged on the HP baseline.
  3. Current system. Furnace-only to AC-only is treated as a cooling addition: haul-away checkbox disabled; the price banner states that coil, line set, circuit and retained heating are not priced—this is not presented as a full installed project total. Fuel changes surface optional gas-piping or gas-cap lines; venting stays a quote exclusion even when gas piping is checked.
  4. Extras. Optional removal from HomeGuide furnace disposal-if-excluded $150-$400 (Dec 31 2025; off by default on heat pumps; disabled on furnace-to-AC additions); optional Angi Insider HVAC permit $250-$400 (Oct 30 2026; off by default on heat pumps — Angi DIY vs Pro usually covers permits; Cost Factors $50-$300 disclosed separately); thermostat $120-$260; minor/replace ducts with sheet-metal labor; electrical and gas-piping options.
  5. Operating cost. Shared delivered heat load with AFUE applied once; equal cooling load for cooling systems; EIA state electricity and gas only for fuels used. Heating and cooling energy shares each round to the nearest $10; the yearly energy total is the sum of those rounded shares.
  6. 10-year cost. Typical installed + 10 × annual operating cost (already rounded as above).
  7. $/yr of life. Typical installed ÷ planning life years. Life years are illustrative midpoints inside common residential ranges (not a surveyed quote field): 18 years for central AC, ducted heat pump and matched AC + furnace; 20 years for gas furnace. Units are dollars per year of assumed service life.
  8. Location. Labor only, by trade wage index from the official OEWS pack (385 metros). Provenance L/S/U is shown per active trade with full CBSA name.
  9. Rounding. Every installed line to the nearest $10; installed total is the sum of rounded lines. Energy uses the same $10 unit on each share, then sums. Planning range is the midpoint of low/typical and typical/high.

Not included in the base capacity price: structural repair, asbestos or mold work, design fees, financing, utility rebates, and the section 25C tax credit. Prices last checked November 25, 2026.

Assumptions labeled as ours

  • Labor share 40% on equipment-plus-install lines
  • Default delivered annual heat load of 60 MMBtu
  • 1,000 cooling full-load hours for the cooling delivered-Btu formula
  • Matched-package per-ton table is our planning interpolation inside HomeGuide $5,000-$11,000 and This Old House $5,000-$12,500 anchors (sources do not publish by-ton package rows)
  • Heat-pump air-handler inclusion and haul-away treated as site-quote / our assumption when Angi by-ton text is ambiguous; handler never auto-added; removal and permit default off; optional permit is an incremental add-on only
  • HomeGuide heat-pump $10,000-$25,000+ with-handler footnote is a different scope from Angi by-ton entry (disposal other-addition $200-$500 disclosed, not auto-added)
  • Optional electrical-work planning band $250-$2,500 and optional gas-cap / gas-line planning bands
  • Planning life years of 18 (AC / heat pump / matched package) and 20 (gas furnace) for $/yr of life only — illustrative midpoints, not sourced warranty or survey medians
  • HomeGuide 5-ton basic installed published as $7,000-$9,500+ (ductwork excluded); model numeric high $9,500 is an illustrative cutoff only
  • Planning range as midpoints of our low/typical/high totals, not a survey of quotes

Matched AC + furnace capacity table (our interpolation)

Exact anchors: HomeGuide HVAC combined change-out with existing ducts $5,000-$11,000 (August 27, 2025); This Old House AC plus furnace with simple ducts $5,000-$12,500 (June 12, 2026). Formula: keep low near the shared $5,000 floor through the 3-ton class, then step low upward; raise typical and high with cooling class so the 3-ton typical sits near the HomeGuide midpoint and the 5-ton high reaches the This Old House $12,500 upper. Derivative method—not a sourced per-ton schedule.

Cooling class (our label)Model lowModel typicalModel high
1.5 ton class$5,000$7,000$10,000
2 ton class$5,000$7,500$10,500
2.5 ton class$5,000$7,800$10,800
3 ton class$5,000$8,000$11,000
3.5 ton class$5,500$8,500$11,500
4 ton class$6,000$9,000$12,000
5 ton class$6,500$9,500$12,500
Rendered types.acFurnace.sizes after our interpolation. Not published HomeGuide/TOH per-ton rows.

Sources

  • HomeGuide, AC Replacement Cost (July 25, 2025): AC costs by tons (capacity): equipment low/high and installed low/high — 1.5: $2,200-$3,500 / $4,700-$6,500; 2: $2,500-$3,800 / $5,000-$6,800; 2.5: $2,900-$4,200 / $5,400-$7,200; 3: $3,300-$4,800 / $5,800-$7,800; 3.5: $3,700-$5,300 / $6,200-$8,300; 4: $4,000-$5,800 / $6,500-$8,800; 5: $4,500-$6,500 / $7,000-$9,500+ (open-ended published upper; ductwork changes excluded). Scope: basic installation, not including ductwork. Also SEER installed table (overlap, not added); minor ducts $300-$1,500; replacement ducts $1,400-$5,600+; ~500-600 sq ft per ton rule of thumb with caveats.
  • HomeGuide, Gas Furnace Prices (December 31, 2025): Installed bands by labeled BTU size: 40-50k $3,800-$6,700; 50-60k $4,200-$7,200; 60-70k $4,700-$8,000; 70-90k $5,100-$9,500; 90-120k $5,800-$12,000. Type label BTU not explicit input/output. AFUE installed: 80-89% $3,800-$6,200; 90-95% $5,200-$8,800; 96%+ $7,500-$12,000. Capacity and efficiency tables overlap. Disposal if excluded $150-$400; minor ducts $300-$1,500; replacement ducts $1,400-$5,600+.
  • Angi, How Much Does a Heat Pump Cost (October 28, 2026): Canonical host www.angi.com. Capacity tons / installed: 2 $3,500-$5,500; 2.5 $3,700-$5,800; 3 $3,900-$6,200; 3.5 $3,900-$6,400; 4 $4,000-$7,300; 5 $4,500-$8,800. Air-handler and disposal inclusion not unambiguously stated. DIY vs Pro: labor usually covers local permits. Cost Factors separately lists permits $50-$300. Model uses by-ton installed rows as HP baseline; does not auto-add handler, haul-away, or a separately assumed permit fee.
  • HomeGuide, Heat Pump Cost (October 30, 2025): Air-source heat pump installed $10,000-$25,000+ explicitly with air handler in the footnote — a different scope from Angi’s by-ton entry band, not a same-area/size certified equivalent. Other additions include disposal $200-$500. Disclosed for contrast; model does not auto-add a handler or that disposal band onto Angi capacity prices or claim the Angi-to-HomeGuide gap is entirely the handler.
  • HomeGuide, HVAC Cost (August 27, 2025): Combined change-out with existing ducts $5,000-$11,000; full new ducts $7,000-$16,000. Used for matched AC+furnace package pricing (not AC installed + furnace installed).
  • Angi, Insider Price Guide for New Heating and Cooling (October 30, 2026): HVAC permit $250-$400; thermostat $120-$260; furnace $3,800-$10,000; ducted heat pump $4,500-$8,000.
  • This Old House, HVAC Installation Cost (June 12, 2026): AC+furnace simple ducts $5,000-$12,500; standalone AC $4,000-$8,000; gas furnace $3,800-$10,000; air-source heat pump $4,500-$8,000.
  • ENERGY STAR, Air-Source Heat Pumps Key Product Criteria: Voluntary criteria; page shows no displayed publication date; checked November 25, 2026. Ducted split HSPF2/SEER2/EER2 7.8/15.2/11; cold-climate ducted HSPF2 8.1 / SEER2 15.2; COP at 5 F >= 1.75; capacity at 5 F >= 70% of capacity at 47 F.
  • U.S. DOE Building America, Manual J and Manual S fact sheet (31318.pdf): Load calculation (Manual J) then equipment selection (Manual S). Cited to reject square-footage-as-certainty sizing.
  • IRS Instructions for Form 5695 (2025), What’s New: No energy efficient home improvement credit (section 25C) for expenditures or property placed in service after December 31, 2025.
  • U.S. Energy Information Administration, Electric Power Monthly Table 5.6.B: US residential electricity 18.19 cents/kWh year to date through September 2026; state YTD prices in energy.json (same pack as water heater).
  • U.S. Energy Information Administration, Natural Gas Prices: US residential natural gas $15.34/Mcf 2025 annual; state averages with labeled 2024 fallback where 2025 is unpublished.
  • U.S. Energy Information Administration, natural gas heat content: 1,000 cubic feet = 1.037 million Btu.
  • U.S. Bureau of Labor Statistics, OEWS May 2025: Hourly mean wages via official wave pack OESServices release 2025A01 for 49-9021, 47-2211, 47-2111, 47-2152. 385 eligible metros with core 49-9021 direct observation. Provenance L/S/U per SOC.

HVAC cost FAQ

How much does it cost to replace a 3-ton central air conditioner?

About $7,410 for a like-for-like swap with removal and permit at US average labor, in a full range of $6,200 to $8,600, using HomeGuide’s 3-ton installed band of $5,800 to $7,800 as the equipment-plus-install base.

Should I replace the furnace and AC together?

Sometimes. A matched change-out in our model is about $8,610 typical for a 3-ton-class package, versus about $7,410 for AC-only and $6,960 for furnace-only. Replacing only one side can leave a mismatched coil and outdoor unit. Compare the same scope: do not add the two standalone totals and call that a package price.

Is a heat pump cheaper to run than a gas furnace?

Compare the heating shares on the same delivered heat load. At 60 MMBtu delivered and US average EIA prices, furnace heating is about $960 per year at 92% AFUE, while the heat-pump heating share is about $1,460 at HSPF2 7.5 (cooling share about $460; rounded shares sum to $1,920 combined). That combined total is not the same scope as furnace-only. Change the delivered load and your state in the calculator.